9073490060004-140
7349 006.000
|
6.00 mm x 97.00 mm OAL; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 006.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490060024-140
7349 006.002
|
6.00 mm x 75.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 006.002]
|
|
hidden
|
hidden
|
hidden
|
|
9073490080004-140
7349 008.000
|
8.00 mm x 106.50 mm OAL; 2 Coolant Ducts; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 008.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490080014-140
7349 008.001
|
8.00 mm x 116.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)[Ground from 7349 008.001]
|
|
hidden
|
hidden
|
hidden
|
|
9073490100004-140
7349 010.000
|
10.00 mm x 131.40 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 010.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490120004-140
7349 012.000
|
12.00 mm x 155.70 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 012.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490140004-140
7349 014.000
|
14.00 mm x 182.48 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 014.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490160004-140
7349 016.000
|
16.00 mm x 204.70 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 016.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490180004-140
7349 018.000
|
18.00 mm x 223.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 018.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490200004-140
7349 020.000
|
20.00 mm x 244.70 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 140º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) [Ground from 7349 020.000]
|
|
hidden
|
hidden
|
hidden
|
|
9073490060004
7349 006.000
|
6.00 mm x 98.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
98
|
3.8583
|
|
9073490060024
7349 006.002
|
6.00 mm x 76.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
76
|
2.9921
|
|
9073490080004
7349 008.000
|
8.00 mm x 107.50 mm OAL; 2 Coolant Ducts; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
8
|
0.3150
|
107.5
|
4.2323
|
|
9073490080014
7349 008.001
|
8.00 mm x 117.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
8
|
0.3150
|
117.5
|
4.6260
|
|
9073490100004
7349 010.000
|
10.00 mm x 132.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
10
|
0.3937
|
132.5
|
5.2165
|
|
9073490120004
7349 012.000
|
12.00 mm x 157.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
12
|
0.4724
|
157
|
6.1811
|
|
9073490140004
7349 014.000
|
14.00 mm x 184.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
14
|
0.5512
|
184
|
7.2441
|
|
9073490160004
7349 016.000
|
16.00 mm x 206.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
16
|
0.6299
|
206.5
|
8.1299
|
|
9073490180004
7349 018.000
|
18.00 mm x 225.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
18
|
0.7087
|
225.5
|
8.8780
|
|
9073490200004
7349 020.000
|
20.00 mm x 247.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
20
|
0.7874
|
247
|
9.7244
|