READY2RUN: DRILLING 7XD

7xD, GROUND h6, 6mm - 25mm DIA, CUT TO LENGTH, with 120° POINT & CHAMFERED COOLANT SLOT

...
Showing: 1-10
Sort by
California Proposition 65 Warning
EDP # Details Diameter OAL
Ground Series   Order Code mm inch mm inch
9073490060004
7349   006.000
6.00 mm x 98.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 6 0.2362 98 3.8583
9073490060024
7349   006.002
6.00 mm x 76.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 6 0.2362 76 2.9921
9073490080004
7349   008.000
8.00 mm x 107.50 mm OAL; 2 Coolant Ducts; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 8 0.3150 107.5 4.2323
9073490080014
7349   008.001
8.00 mm x 117.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 8 0.3150 117.5 4.6260
9073490100004
7349   010.000
10.00 mm x 132.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 10 0.3937 132.5 5.2165
9073490120004
7349   012.000
12.00 mm x 157.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 12 0.4724 157 6.1811
9073490140004
7349   014.000
14.00 mm x 184.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 14 0.5512 184 7.2441
9073490160004
7349   016.000
16.00 mm x 206.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 16 0.6299 206.5 8.1299
9073490180004
7349   018.000
18.00 mm x 225.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 18 0.7087 225.5 8.8780
9073490200004
7349   020.000
20.00 mm x 247.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 20 0.7874 247 9.7244