READY2RUN: DRILLING 5XD

5xD, GROUND h6, 6mm - 25mm DIA, CUT TO LENGTH, with 120° POINT & CHAMFERED COOLANT SLOT

...
Showing: 1-12
Sort by
California Proposition 65 Warning
EDP # Details Diameter OAL
Ground Series   Order Code mm inch mm inch
0
7916   006.000
6.00 mm x 83.0mm OAL; Ground to h6 Tol; BC 2.6mm; d 0.7mm; Pitch 32.65mm; 140° point on one end; chip groove on one end B 1.0mm T 1.2mm; DK460UF/GC100S(10% Co)
hidden
hidden
hidden
900791-4
7916   008.000
8.00 mm x 92.50 mm OAL; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53mm; 140°point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
hidden
hidden
hidden
9079160250004
7916   025.000
25.00 mm x 169.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 12.00 mm; d 2.50 mm; Pitch 136.03 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
hidden
hidden
hidden
9079160060004
7916   006.000
6.00 mm x 83.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 120º point on one end; chip groove on one end B 1.00 mm T 1.20 mm; DK460UF/GC100S (10% Co) 6 0.2362 83 3.2677
9079160060014
7916   006.001
6.00 mm x 75.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 120 degree point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 6 0.2362 75 2.9528
9079160080004
7916   008.000
8.00 mm x 92.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 8 0.3150 92.5 3.6417
9079160100004
7916   010.000
10.00 mm x 104.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 10 0.3937 104.5 4.1142
9079160120004
7916   012.000
12.00 mm x 120.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 12 0.4724 120 4.7244
9079160140004
7916   014.000
14.00 mm x 126.0 mm OAL; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 14 0.5512 126 4.9606
9079160160004
7916   016.000
16.00 mm x 135.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 16 0.6299 135.5 5.3346
9079160180004
7916   018.000
18.00 mm x 145.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 18 0.7087 145.5 5.7283
9079160200004
7916   020.000
20.00 mm x 156.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 20 0.7874 156 6.1417