|
9079150060004
7915 006.000
|
6.00mm x 67.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.7 mm; Pitch 32.65 mm; 120º point on one end; chip groove on one end B 1.0 mm T 1.2 mm; DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
67
|
2.6378
|
|
9079150060014
7915 006.001
|
6.00mm x 67.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.8 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
67
|
2.6378
|
|
9079150060024
7915 006.002
|
6.00mm x 63.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 1.50 mm; d 0.6 mm; Pitch 20.40 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
63
|
2.4803
|
|
9079160060004
7916 006.000
|
6.00 mm x 83.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 120º point on one end; chip groove on one end B 1.00 mm T 1.20 mm; DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
83
|
3.2677
|
|
9079160060014
7916 006.001
|
6.00 mm x 75.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 120 degree point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
75
|
2.9528
|
|
9073490060004
7349 006.000
|
6.00 mm x 98.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
98
|
3.8583
|
|
9073490060024
7349 006.002
|
6.00 mm x 76.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
6
|
0.2362
|
76
|
2.9921
|
|
9073490080004
7349 008.000
|
8.00 mm x 107.50 mm OAL; 2 Coolant Ducts; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
8
|
0.3150
|
107.5
|
4.2323
|
|
9073490080014
7349 008.001
|
8.00 mm x 117.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
8
|
0.3150
|
117.5
|
4.6260
|
|
9079160080004
7916 008.000
|
8.00 mm x 92.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
8
|
0.3150
|
92.5
|
3.6417
|
|
9079150080004
7915 008.000
|
8.00mm x 80.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
8
|
0.3150
|
80.5
|
3.1693
|
|
9079150100004
7915 010.000
|
10.00mm x 90.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.4 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
10
|
0.3937
|
90.5
|
3.5630
|
|
9079160100004
7916 010.000
|
10.00 mm x 104.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
10
|
0.3937
|
104.5
|
4.1142
|
|
9073490100004
7349 010.000
|
10.00 mm x 132.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
10
|
0.3937
|
132.5
|
5.2165
|
|
9073490120004
7349 012.000
|
12.00 mm x 157.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
12
|
0.4724
|
157
|
6.1811
|
|
9079160120004
7916 012.000
|
12.00 mm x 120.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
12
|
0.4724
|
120
|
4.7244
|
|
9079150120004
7915 012.000
|
12.00mm x 104.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
12
|
0.4724
|
104
|
4.0945
|
|
9079150140004
7915 014.000
|
14.00mm x 109.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
14
|
0.5512
|
109
|
4.2913
|
|
9079160140004
7916 014.000
|
14.00 mm x 126.0 mm OAL; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
14
|
0.5512
|
126
|
4.9606
|
|
9073490140004
7349 014.000
|
14.00 mm x 184.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
14
|
0.5512
|
184
|
7.2441
|
|
9073490160004
7349 016.000
|
16.00 mm x 206.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
16
|
0.6299
|
206.5
|
8.1299
|
|
9079160160004
7916 016.000
|
16.00 mm x 135.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
16
|
0.6299
|
135.5
|
5.3346
|
|
9079150160004
7915 016.000
|
16.00mm x 117.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S(10% Co)
|
16
|
0.6299
|
117.5
|
4.6260
|
|
9079150180004
7915 018.000
|
18.00mm x 125.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
18
|
0.7087
|
125.5
|
4.9409
|
|
9079160180004
7916 018.000
|
18.00 mm x 145.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
18
|
0.7087
|
145.5
|
5.7283
|
|
9073490180004
7349 018.000
|
18.00 mm x 225.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
18
|
0.7087
|
225.5
|
8.8780
|
|
9073490200004
7349 020.000
|
20.00 mm x 247.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
20
|
0.7874
|
247
|
9.7244
|
|
9079160200004
7916 020.000
|
20.00 mm x 156.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co)
|
20
|
0.7874
|
156
|
6.1417
|
|
9079150200004
7915 020.000
|
20.00mm x 134.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co)
|
20
|
0.7874
|
134
|
5.2756
|